Hitachi Koki DS 14DSFL Instrucciones De Seguridad Y Manual De Instrucciones página 14

Ocultar thumbs Ver también para DS 14DSFL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
3.
Charging
When the battery is connected to the battery
charger, charging will commence and the pilot
lamp will light in red. (See Table 2)
NOTE
If the pilot lamp does not light or blink in red, pull
out the plug from the receptacle and check if the
battery is properly mounted.
Before
charging
While
charging
Charging
complete
Pilot lamp
(red)
Overheat
standby
Charging
impossible
Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in Table 3, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 3
Rechargeable
batteries
BSL1415, BSL1815
4.
Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5.
Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
14
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights for 1 second. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light
Flickers for 0.1 seconds. (off for 0.1 seconds)
Temperatures at which the
battery can be recharged
32°F —122°F (0°C — 50°C)
When the battery is fully charged, the pilot lamp
will blink in red slowly. (At 1-second intervals) (See
Table 2)
Table 2
discharge might be low when using them the first
and second time. This is a temporary
phenomenon, and normal time required for
recharging will be restored by recharging the
batteries 2 – 3 times.
CAUTION
● When the battery charger has been continuously
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
charging has been completed, give 15 minutes rest
until the next charging.
● If the battery is charged while it is heated because
it has been left for a long time in a location subject
to direct sunlight or because the battery has just
been used, the pilot lamp of the charger lights for
1 second, does not light for 0.5 seconds (off for
0.5 seconds).
The battery will not be recharged. In such a case,
let the battery cool before charging.
● When the pilot lamp flickers (at 0.2-second
intervals), check for and take out any foreign
objects in the charger's battery connector. If there
are no foreign objects, it is probable that the
battery or charger is malfunctioning. Take it to
your authorized Service Center.
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Malfunction in the
battery or the charger

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ds 18dsfl

Tabla de contenido