Descargar Imprimir esta página

Thetford TECMA 2G Silence Plus Toilet Manual De Instalacion Y Uso página 5

Publicidad

Installation - con't.
Discharge Hoses
This toilet is designed to discharge waste into a 1.5" ID high-quali-
ty sanitation hose/pipe.
Use only high-quality reinforced hoses for
AVISO
AVIS
!
NOTICE
CAUTION
installation. Rigid PVC pipe may also be used
for the discharge line. If using fl exible hoses,
avoid sharp bends that may cause the hose
to kink and restrict fl ow, and secure the hoses
to prevent abrasion. Always inspect the fi nal
installation for leaks.
Vehicle Electrical Requirements
Installation requirements:
■ All circuits must follow RVIA standards.
■ Wire gauge sizes must follow Wire Gauge Size Chart.
■ Every toilet must have its own circuit breaker or fuse.
■ Always use crimp-style connectors with Sealing provisions to
avoid corrosion.
HAZARD OF FIRE:
AVISO
AVIS
!
!
!
!
NOTICE
ATTENTION
ATENCIÓN
CAUTION
DANGER
ATTENTION
ATTENTION
ATTENTION
Always use recommended circuit breakers or
fuses. Failure to follow the recommendations
can result in fi re.
Wire Gauge Size Chart
If source* is:
12 VOLTS - Install
24 VOLTS - Install
* Distance measured assumes power and ground wires
Wall Switch & Wiring
Select wall switch location convenient to toilet. Cut hole 2- 5/8" x 3-3/4" and drill holes for mounting screws.
Tecma® 2G Silence Plus Toilet RV Owner's & Installation Manual
0-20 feet
10 Gauge
16 Gauge
.60"
.60"
15 mm
15 mm
3.23"
3.23"
82 mm
82 mm
.35" ,9 mm
.35" ,9 mm
Side /
Side /
Côté / Lado
Côté / Lado
Mounting Location
■ Ideally, the Tecma® toilet should be installed in a location that
is higher than the holding tank. A (maximum) 6' rise between
the toilet and holding tank will not impact performance.
■ Using toilet and supplied template, verify that the installation
site has:
suffi cient clearance between toilet and nearby wall so that
water supply hose and discharge hose are not kinked
room for maintenance accessibility
suffi cient room to house the pump (Low Model only)
■ The fl oor supporting the toilet is level and strong enough to
support toilet and weight of any potential user.
■ The fl oor structure is strong enough to securely anchor toilet
using supplied screws; 3/4" minimum.
■ The fl ooring is water-resistant so structure and anchoring
integrity are maintained.
Bezel Installation
When planning the installation be sure to consider:
■ Bezel placement wall thickness; refer to Fig. E.
■ Distance between toilet and bezel; the harness is 12' in length
or less
HAZARD OF FIRE:
AVISO
AVIS
!
!
!
!
NOTICE
ATTENTION
ATENCIÓN
CAUTION
DANGER
ATTENTION
ATTENTION
ATTENTION
Always use recommended circuit breakers or
fuses. Failure to follow the recommendations
can result in fi re.
20-32 Feet
8 Gauge
14 Gauge
Fig. D
Cutout /
3.70"
3.70"
94 mm
94 mm
FLUSH
FLUSH
2.60"
2.60"
66 mm
66 mm
4.8"
4.8"
122 mm
122 mm
Fig. E
5
33-50 feet
Circuit Breaker
6 Gauge
30 amp
Fuse
12 Gauge
30 amp
Fuse
Découpe / Recorte
T000010A
A4.2
T000031B
T000031B
98269 Rev. D (06.14.19)

Publicidad

Capítulos

Solución de problemas

loading