Installation, con't.
Connect Electrical
Mount Tank Sensors
Full Tank Sensor / Mid Tank Sensor (Optional)
■ Clean the surface of the side of the tank at the top – approx-
imately on the left-right centerline with isopropyl alcohol (not
included) where the Full Tank Sensor will be mounted. When
thoroughly clean and dry, fi rmly press the sensor in place.
Wires can point in any direction – the sen-
NOTICE
sors directional orientation does not affect its
operation.
■ Follow the same procedure for the Mid Tank Sensor, except it
should be mounted on the left-right centerline approximately
half way up the tank side.
■ The Full Tank Sensor is mounted at the highest point on the
tank minus one inch (to allow for a few additional fl ushes)
from tank capacity, or where the installer wants the Tank Full
indication to be.
■ The Tank Sensors should be mounted near the center line of
the tank.
A6.1
A6.2
Keep wires away from sensor pads to avoid
NOTICE
false readings.
A6.1
A6.2
Refer to Fig. B and Fig. G.
Ref.
Description
A6.1
FULL Tank Sensor - The sensor has a removable cover over
the pressure-sensitive adhesive pad.
A6.2
Mid Tank Sensor (Optional) - The sensor has a removable
cover over the pressure-sensitive adhesive pad.
B5
The area for adhesion should be thoroughly cleaned with alco-
hol or equivalent, and dried, prior to mounting the sensor.
98269 Rev. D (06.14.19)
Holding Tank
Holding Tank Centerline
B5
Fig. F
Tecma® 2G Silence Plus Toilet RV Owner's & Installation Manual
6