CARE AND MAINTENANCE
WARNING
Risk of Explosion. Disconnect,
tag and lock out power source,
then release all pressure from the
system before attempting to install,
service, relocate or perform any
maintenance.
All repairs should be performed by an authorized service representative.
For efficient operation, perform the following maintenance.
1. Disconnect, tag and lock out power source;
clean debris from motor, flywheel, tank, air
lines and pump cooling fins.
2. Maintain proper oil level. Refer to Lubrication
section for details.
3. Change oil.
a. Allow compressor to run and warm up
oil. Disconnect, tag and lock out power
source.
b. Position a pan under pump.
c. Remove oil drain plug (See Figure 1).
Allow oil to collect in pan.
d. Replace drain plug, fill pump to full level
(See Figure 1). See Lubrication section of
this manual.
4. Drain Tank. Disconnect, tag and lock out
power source; release pressure. Drain
moisture from tank by opening drain valve
underneath tank (See Figure 2).
5. Check air filter to be sure it is clean. Replace
filter if filter is dirty.
NOTICE
Unit Care and Maintenance. Drain liquid from
tank daily.
1
2
18
Oil Fill
Oil Drain
Plug
kobalttools.com
Plug