Husqvarna PG 540 Manual Del Usuario página 11

Ocultar thumbs Ver también para PG 540:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Set the handle in servicing position. Refer to
positions on page 12 .
4. If weights are installed, adjust the weights to a
rearward position. Refer to
page 16 .
5. Hold the handlebar and tilt the product rearward. Tilt
the product until the handlebar is on the floor.
WARNING: Make sure that the product
is in a stable position before you replace
the diamond tools.
6. Put on protective gloves.
7. Turn the tool plate (C) to the right or to the left to
unlock the tool plate from the grinding disc.
8. Pull the tool plate straight out (D) to remove the tool
plate from the grinding disc.
9. Use a hammer to remove the diamond tools from the
tool plate.
1211 - 003 - 22.01.2020
Handle
To adjust the weights on
C
D
10. Attach new diamond tools to the tool plate with a soft
hit of the hammer.
11. Attach the tool plate straight (E) on the grinding disc.
12. Turn the tool plate (F) to the right or to the left to lock
the tool plate to the grinding disc.
13. Carefully lift the product with the handlebar to
operation position.
To connect a dust extractor
WARNING: Do not use the dust extractor if
the dust extractor hose is damaged. The risk
increases that you breathe in dust that is
dangerous to your health. Use approved
respiratory protection.
1. Examine the dust extractor hose for damages.
2. Make sure that the filters in the dust extractor are
clean and not damaged.
3. Make sure that the STOP/RUN switch on the control
panel is set to 0.
E
F
11

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido