Descargar Imprimir esta página

Publicidad

EN
Figure 4 is a typical installation shown with all the recommended
accessories for the pump to operate correctly.
NOTE: The compressed air supply must be set between 29 and 200
psi (2 and 14 bar), being 90 psi (6 bar) the recommended pressure.
An air closing valve must be installed, in order to be able to close the
compressed air line at the end of the day (If the air inlet not is closed
and there is a leakage in some point of the grease outlet circuit, the
pump will start automatically, emptying the container).
A título informativo, se muestra en la figura 4 una instalación típica
Pos
Description
A
Air shut off valve
B
Filter regulator
C
Air hose
D
Quick coupling
E
Connection nipple
F
Pump, 408 lb (185 kg) drum
G
Grease hose
H
Grease shut off valve
I
Cover
J
Follower plate
K
Pressure Relief Valve
4
853 814 R. 06/17
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa USA • Phone (828) 686-8511 • Fax (828) 686-8533
Typical installation / Conexión tipo de la bomba
39.37 in
K
Fig. 5
ES
con todos los elementos recomendados para su correcto
funcionamiento.
NOTA: La presión de alimentación de aire debe estar comprendida
entre 29 y 200 psi (2 y 14 bar) siendo 90 psi (6 bar) la presión
recomendada. Es aconsejable instalar, asimismo, una válvula de cierre
para poder cerrar la alimentación de aire al final de la jornada (en
caso de roturas o fugas en la salida de grasa, si la alimentación de aire
no está cerrada, la bomba se pondría en marcha automáticamente,
pudiendo vaciarse completamente el depósito).
59.06 in
Descripción
Válvula de corte de aire
Filtro regulador
Manguera de aire
Enchufe rápido
Conector rápido
Bomba, bidón 408 lb (185 kg)
Manguera grasa
Válvula de cierre de grasa
Tapa
Plato seguidor
Válvula de descarga
Part No. / Cod.
950319+239004
241001
362100
251412
255412
531410
412392
950304
418026
417004

Publicidad

loading

Este manual también es adecuado para:

531410531420531430531411531421531431