Checking Burner Cap Placement
Check to make sure that there is no gap between the
burner parts. You may gently try to move the burner
parts from side to side to check if they are properly
placed.

Check the Installation

Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow
tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LPG Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that
the regulator is set for the correct fuel. After
adjustment, retest.
Some yellow streaking is normal during the initial
start-up. Allow unit to operate 4-5 minutes and re-
evaluate before making adjustments.