Riello RS 34/M MZ Instrucciones De Instalación, Funcionamiento Y Mantenimiento página 4

Quemadores de gas de aire soplado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The burner has EC marking and conforms to the basic requisites of the following Directives:
– EC Reg. N.: 0085BR0378 in accordance with 90/396/EEC;
– Electromagnetic Compatibility Directive 2004/108/EC;
– Low voltage directive 2006/95/EC;
– Machine Directive 2006/42/EC;
The burner meets protection level of IP 40 as EN 60529.
IDENTIFICATION
The Identification Plate on the product gives the serial number, model and main technical and perform-
ance data. If the Identification Plate is tampered with, removed or missing, the product cannot be clearly
identified, thus making any installation or maintenance work potentially dangerous.
GENERAL WARNINGS
The dimension of the boiler's combustion chamber must respond to specific values, in order to guaran-
tee a combustion with the lowest polluting emissions rate.
You are therefore advised to consult the Technical Assistance Department before choosing this type of
burner for the combination with a boiler.
Qualified personnel are those with the professional and technical requirements indicated by Law no.
46 dated 5 March 1990. The commercial organisation has a widespread network of agencies and tech-
nical offices whose personnel participates periodically in instructional and refresher courses at the
company training centre.
This burner must only be used for the application it was designed for.
The manufacturer cannot accept responsibility for any damage to persons, animals or property due to
errors in installation or in the burner adjustment, or due to improper or unreasonable use or non-observ-
ance of the technical instructions enclosed with the burner, or due to the intervention of unqualified per-
sonnel.
USER INFORMATION
If faults arise in ignition or operations, the burner performs a "safety stop", which is signalled by the
red burner lock out LED. To rearm start-up conditions, press the release button. When the burner
starts up again, the red LED goes out.
This operation can be repeated for a maximum of 3 times. If the "safety stop" recurs, then the
Technical Assistance Centre must be contacted.
BASIC SAFETY RULES
Children or inexpert persons must not use the appliance.
Under no circumstances must the intake grids, dissipation grids and ventilation vents in the installa-
tion room be covered up with cloths, paper or any other material.
Unauthorised persons must not attempt to repair the appliance
It is dangerous to pull or twist the electric leads.
Cleaning operations must not be performed if the appliance is not disconnected from the main power
supply.
Do not clean the burner or its parts with inflammable substances (e.g. petrol, alcohol, etc.).
The cover must be cleaned with soapy water.
Do not place anything on the burner.
Do not leave containers and inflammable products in the installation room.
The following symbols are used in this manual:
!
ATTENTION = for actions requiring special care and adequate preparation.
FORBIDDEN = for actions THAT MUST NOT be performed.

Publicidad

Tabla de contenido
loading

Tabla de contenido