LiftMaster LA412 Guia De Inicio Rapido
Ocultar thumbs Ver también para LA412:

Publicidad

Idiomas disponibles

Idiomas disponibles

QuickStar t
for single gate application
LA412DC
Primary 12 VDC Actuator Arm for
single swing gate applications
LA412DCS
Secondary 12 VDC Actuator Arm for
dual swing gate applications
LA412PKGU
Single Arm Package
2016 UL 325 Gate Operators require use of LiftMaster
external monitored entrapment protection devices.
This QuickStart is intended to highlight a single gate
application. Each application is unique and it is the
responsibility of the purchaser, installer and end user to ensure
that the total gate system is installed and operated properly.
Refer to the installation manual for complete information
regarding installation, testing, and programming.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
LiftMaster.com
01-38140
© 2016, LiftMaster – All Rights Reserved
Attach brackets to operator
Determine mounting location
TOP VIEW OF GATE
Post bracket
Install the Control Box
Earth Ground Rod
Check national
and local codes
for proper depth
INSTALLATION
Position the operator
Gate hinge center
7" (17.8 cm)
7" (17.8 cm)
Install the Solar Panel
Install the earth ground rod
within 3 feet (.9 m) of the
control box. The ground wire
must be a single, whole piece of
wire.
Secure the brackets
Connect the Operator Arm to the Control Box
Install facing
south.

Publicidad

Tabla de contenido
loading

Resumen de contenidos para LiftMaster LA412

  • Página 1 7" (17.8 cm) LA412PKGU Single Arm Package Post bracket 7" (17.8 cm) 2016 UL 325 Gate Operators require use of LiftMaster external monitored entrapment protection devices. Install the Control Box Earth Ground Rod Install the Solar Panel Connect the Operator Arm to the Control Box This QuickStart is intended to highlight a single gate application.
  • Página 2: Wiring And Adjustments

    This operator contains an inherent (internal) entrapment protection (see images below). Refer to your manual for complete wiring gate is stopping at the proper open and close limit positions. system and REQUIRES the addition of a LiftMaster external The gate MUST be attached to information.
  • Página 3: Démarrage Rapide

    être un fil simple l’installation, la mise à l’essai et la programmation. nationaux et locaux d’une seule pièce. pour la profondeur appropriée. 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com 01-38140 © 2016, LiftMaster – Tous droits réservés...
  • Página 4 La barrière DOIT être fixée à fermeture. les batteries (voir les illustrations ci-dessous). Consulter le protection de LiftMaster contre le piégeage (capteur l’actionneur avant le réglage des manuel pour les instructions complètes de câblage. 2. Placer un objet solide entre la barrière ouverte et une structure rigide.
  • Página 5: Instalación

    El nacionales y locales conductor de tierra debe ser para averiguar la un cable entero (de una sola profundidad correcta. pieza). 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com 01-38140 © 2016, LiftMaster – Reservados todos los derechos de ley...
  • Página 6 (ver las siguientes ilustraciones). El portón DEBE estar acoplado al 2. Colocar un objeto sólido entre la trayectoria de apertura y una monitoreada de LiftMaster para CADA zona de atrapamiento Consultar el manual para obtener las instrucciones completas operador antes de regular los estructura fija.

Este manual también es adecuado para:

La412dcLa412dcsLa412pkgu

Tabla de contenido