FEATURES
CONTROL PANEL COMPONENTS
1
1. Fuel Selector Switch: Used to select gas or propane
operation.
2. Push-Button START/STOP: Push once to
automatically start the engine. Push again to stop
the engine.
3. Battery Switch: Turns battery ON and OFF. Must be
ON before electric or remote start.
4. USB Ports: Two-port 5V/2.1A USB outlet. Accepts
Type A USB plugs.
5. Main Circuit Breaker: The main circuit breaker controls
total output of all outlets to protect the generator from
overload or short circuit.
6. 120 Volt AC, 20 Amp Duplex GFCI NEMA 5-20R
Receptacles: Receptacles can supply a maximum of
20 Amps.
7. 120/240 Volt AC, 30 Amp NEMA 14-30R Twist-Lock
Receptacle: Receptacle can supply a maximum of
30 Amps.
DATA DISPLAY
Voltage:
Displays current voltage
output.
METER V-F-T
Mode Button
10 | Westinghouse Outdoor Power Equipment, LLC
2
3
4
13
12
Frequency (Hz):
Displays power output
frequency in Hertz.
Push the Mode button to cycle through
the data display modes.
5
6
11
9
10
8
8.
20 Amp AC Circuit Breakers: Circuit breakers
limits the current that can be delivered through the
NEMA 5-20R receptacles to 20 Amps.
9.
Ground Terminal: The ground terminal is used to
externally ground the generator.
10. Data Center: Toggle to show voltage, frequency,
total hour meter, and run/maintenance timer.
11. Battery Charging Port: Used to charge the battery
with the included battery charger.
12. Smart Switch Outlet: Connects the Westinghouse
ST Switch (sold separately) to the control panel.
13. Battery Indicator: Indicates that power is ON. Light
will remain illuminated while the unit is ON.
Lifetime Hours:
Displays the lifetime run
hours.
7 7
Run Time/Maintenance:
Displays current run time.
Resets to zero when shut
down. Maintenance
reminder displayed
when required.
Maintenance Codes:
P25: Change engine oil
P50: Clean air filter,
Change engine oil
P100: Change engine oil,
clean air filter, replace
fuel filter