[Eff ectively Using the Quick Cooling Button]
Press the quick cooling button and press the switch to
blow warm air at approximately 50 degrees Celsius for
each of the switch's wind volumes.
This is used to quickly cool material that is heat-
warping and to cool the nozzle when it reaches high
temperatures after using the Heat Gun.

MAINTENANCE AND INSPECTION

1. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that
they are properly tightened. Should any of the screws
be loose, retighten them immediately. Failure to do so
could result in serious hazard.
2. Maintenance of the motor
The motor unit winding is the very "heart" of the power
tool.
Prevent any foreign objects, oil or water from getting
inside the intake.
3. Replacing supply cord
If the replacement of the supply cord is necessary, this
has to be done by HiKOKI Authorized Service Center in
order to avoid a safety hazard.
4. Cleaning of the outside
When the tool is stained, wipe with a soft dry cloth or a
cloth moistened with soapy water. Do not use chloric
solvents, gasoline or paint thinner, as they melt plastics.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
IMPORTANT:
Correct connection of the plug
The wires of the main lead and coloured in accordance
with the following code:
Blue:
-Neutral
Brown:
-Live
As the colours of the wires in the main lead of this tool may
not correspond with the coloured markings identifying the
terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black.
The wire coloured brown must be connected to the terminal
marked with the letter L or coloured red.
Neither core must be connected to the earth terminal.
NOTE:
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except The United Kingdom.