CHANGING THE MAXIMUM INVERTER FAN SPEED

To change the maximum speed of the inverter fan, you must press and hold the AUX button for around 10 seconds, after which you will
hear a sound alert telling you that you have entered maximum speed selection mode. Within the control system you may choose from the
following MaxSpeed options:
In order to select one of the five MaxSpeed options, you simply need to press the AUX button. Your selection is displayed through the
number of green LED lights displayed and through sound alerts. If the AUX button is not pressed for a period of 30 seconds, the control
system will exit the MaxSpeed selection procedure.
Every time a green LED lights up there is a corresponding sound alert.

GREEN LEDS DISPLAYED

When the GLF grid is operating normally, the green LED indicates the following:
1.
Setpoint/season/standard operating mode forced
2.
Timer On or Timer Off mode activated by the VMF-IR remote control
200 ms

ALARM DISPLAY

In the event of any sort of failure, the receiver card will display the type of alarm through various light sequences, using the red and white
LEDs.
white LED: a cycle of 5 lights which then remain switched off for 5 seconds
red LED: lights up at the same time as the white light in order to provide a specific code (see table )
26
MaxSpeed
1^
2^
3^
4^
5^
WHITE AND GREEN LEDS DISPLAYED
DISPLAY
AGLFI10NFJ 2006_5905245_01
Maximum output
6.4V
7.4 V
8.3 V
9.4 V
10.0 V
GREEN LED
WHITE LED
5 SECONDS
RED LED
WHITE LED
ALARM
no alarms
damaged air probe
Anti-freeze
insufficient water levels
E4 interface not connected
fault inverter
damaged heater
condensate discharge
MAX SPEED
1^
2^
3^
4^
5^
DISPLAY #1
DISPLAY #2