Burner Description; Packaging - Weight; Max. Dimensions; Standard Equipment - Riello RS 70 Instrucciones De Instalación, Funcionamiento Y Mantenimiento

Quemadores de gas de aire soplado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

D3030
mm
A
B
RS 70
1300
740
RS 100
1300
740
RS 130
1300
740
D36
mm
A
B
C
D
RS 70
511 296 215 555 840 250 - 385 179 430 1161-1296 214 134 221 2"
RS 100 527 312 215 555 840 250 - 385 179 430 1161-1296 214 134 221 2"
RS 130 553 338 215 555 840 280 - 415 189 430 1161-1296 214 134 221 2"
(1) Blast tube: short-lang
C
kg
682
70
682
73
682
76
E
F
G
H
(1)
(A)
(B)
D731
I
L
M
N
O
(1)
(C)
3
BURNER DESCRIPTION (A)
1 Combustion head
2 Ignition electrode
3 Screw for combustion head adjustment
4 Sleeve
5 Servomotor controlling the gas butterfly
valve and of air gate valve (by means of a
variable profile cam mechanism).
When the burner is stopped the air gate
valve will be completely closed to reduce
heat loss due to the flue draught, which
tends to draw air from the fan air inlet.
6 Extension for slide bars 15)
7 Motor contactor and thermal cut-out reset
button
8 Plug-socket on ionisation probe cable
9 Terminal strip
10 Fairleads for electrical connections by installer
11 Two switches:
- one "burner off-on"
- one for "1st - 2nd stage operation"
12 Control box with lock-out pilot light and lock-
out reset button
13 Flame inspection window
14 Minimum air pressure switch
(differential operating type)
15 Slide bars for opening the burner and
inspecting the combustion head
16 Gas pressure test point and head fixing screw
17 Air pressure test point
18 Flame sensor probe
19 Air gate valve
20 Air inlet to fan
21 Screws securing fan to sleeve
22 Gas input pipework
23 Gas butterfly valve
24 Boiler mounting flange
25 Flame stability disk
Two types of burner failure may occur:
• Control box lock-out: if the control box
12)(A) pushbutton (red led) lights up, it indi-
cates that the burner is in lock-out.
To reset, hold the pushbutton down for
between 1 and 3 seconds.
• Motor trip: release by pressing the pushbut-
ton on thermal cutout 7)(A).
PACKAGING - WEIGHT (B)
Approximate measurements
• The burner stands on a wooden base which
can be lifted by fork-lifts.
Outer dimensions of packaging are indicated
in (B).
• The weight of the burner complete with pack-
aging is indicated in Table (B).
MAX. DIMENSIONS (C)
Approximate measurements
The maximum dimensions of the burner are
given in (C).
Bear in mind that inspection of the combustion
head requires the burner to be opened by with-
drawing the rear part on the slide bars.
The maximum dimension of the burner when
open is give by measurement I.

STANDARD EQUIPMENT

1 - Gas train flange
1 - Flange gasket
4 - Flange fixing screws M 10 x 35
1 - Thermal insulation screen
2 - Extensions 6)(A) for slide bars 15)(A)
(for models with 385-415 mm blast tube)
4 - Screws to secure the burner flange to the
boiler: M 12 x 35
1 - Instruction booklet
1 - Spare parts list