17. Fault Correction

Fault
Water does not flow
Water flows
continuously
The system does not
recognise the sensor
Water flow too weak
Soap does not flow
No air stream
The device is operating
continuously
Air stream too cool
Air stream too hot
Reduced air stream
If you are unable to correct a fault or if the fault is not described in the fault correction section,
please inform our customer service department!
Cause
– Water supply interrupted
– Voltage supply interrupted
– Range incorrectly set
– Solenoid valve faulty
– Sensor faulty
– Solenoid valve dirty
– Solenoid valve faulty
– Sensor is incorrectly programmed
– Sensor faulty
– Water flow volume regulator not fully
opened
– Supply pressure too low
– Grit filter is clogged
– Voltage supply interrupted
– Soap tank empty
– Sensor defective
– Soap pump defective
– Voltage supply interrupted
– Sensor faulty
– Hand dryer defective
– Sensor faulty
– The heater in the hand dryer is
defective
– Heater dirty
– Air channel dirty
– Hand dryer defective
– Air channel dirty
– Hand dryer defective
Remedy
➯ Restore it
➯ Restore it
➯ Adjust it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Reset and log back
in again
➯ Replace it
➯ Open it
➯ Check it
➯ Clean it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Clean it
➯ Replace it
➯ Clean it
➯ Replace it
9