11. Installing the Soap Tank
A: not included in scope of delivery
see accessories
12. Installing Electrical
Warning!
• The electrical connection is to be customer-provided with a suitable switch-off device
and secured with an earth leakage circuit breaker (RCD) for a maximum nominal fault
current of 30 mA.
• Switch off power supply before proceeding.
12.1 To connect the 230 V AC power supply, first remove the cover.
12.2 Press in the perforation.
12.3 Slide the power cables through the cable bushings.
12.4 Connect the power cable to the terminal block (d).
1 green-yellow
2 blue
3 black
12.5 Mount the housing cover.
12.6 Connect the power supply.
13. Logging on Sensors
13.1 Connect the power source (A).
13.2 The electronic module (C) initialises for approx. 15 seconds.
☞
Wait until the flashing stops, one LED is always flashing.
13.3 Connect the extension cable.
13.4 Connect the Y-junction.
☞
The following sequence of work steps must be followed to properly connect the sensors.
Connecting the soap sensor (if included)
13.5 Connect the "soap" sensor (b).
☞
Wait until "soap" sensor (b) stops flashing.
13.6 Disconnect the power source for at least 2 seconds (B).
13.7 Connect the power source (A).
13.8 The electronic module (C) initialises for approx. 15 seconds.
13.9 Allow your hand to approach the "soap" sensor (b) and then hold your hand in front of it
until the soap pump pumps briefly.
6