BTV/QTVR (Hazardous area*)
ATEX / UKCA
SGS20ATEX0048X / BAS21UKEX0497X
II 2 G Ex 60079-30-1 eb IIC T6 Gb
II 2 D Ex 60079-30-1 tb IIIC T80°C Db
BTV
II 2 G Ex 60079-30-1 eb mb IIC T6 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T80°C Db
Tmin –60°C
SGS20ATEX0050X / BAS21UKEX0498X
II 2 G Ex 60079-30-1 eb IIC T4 Gb
II 2 D Ex 60079-30-1 tb IIIC T130°C Db
QTVR
II 2 G Ex 60079-30-1 eb mb IIC T4 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T130°C Db
Tmin –60°C
North America
Um= 277 V max.
Class/division when installed with
E-20
cCSAus Certificate 1333271
Class I Division 2 Group A,B,C,D
BTV
Class II Division 2 Group E, F,G
Class III T6
cCSAus Certificate 1333271
Class I Division 2 Group A,B,C,D
QTVR
Class II Division 2 Group E, F,G
Class III T4
ENGLISH
Specific conditions of use:
Maximum exposure temperature: 110°C (230ºF)
Minimum exposure temperature: –60°C (–76ºF)
Minimum installation temperature: –20°C (–4ºF)
For use with the heating cable types as shown in the table.
Refer to installation manual. A ground fault circuit interrupter shall be
used with this device.
Earth fault equipment protection is required for each circuit.
De-energise circuits before installation or servicing.
Keep ends of Trace heaters and kit components dry before and
during installation.
The electrically conductive covering of this trace heater shall be
connected to a suitable earthing terminal.
The presence of the trace heaters shall be made evident by the
posting of caution signs or markings at appropriate locations and/or
at frequent intervals along the circuit.
The insulation resistance of the trace heater shall be measured and
recorded after installation and shall not less than 20Mohm.
Persons involved in the installation and testing of electric trace heating
systems shall be suitably trained in all special techniques required.
Installation shall be carried out under the supervision of a
qualified person.
4 | nVent.com/RAYCHEM
ООО Центр «ПрофЭкс» ЕАЭС RU C-BE.AЖ58.B.01728/21
1 Ex e IIC T* Gb X
TЕМП ОКР СРЕДЫ –60°C to +56°C
IECEX
IECEx BAS.06.0043X
Ex 60079-30-1 eb IIC T6 Gb
Ex 60079-30-1 tb IIIC T80°C Db
Ex 60079-30-1 eb mb IIC T6 Gb
Ex 60079-30-1 mb tb IIIC T80°C Db
Tmin –60°C
IECEx BAS.06.0045X
Ex 60079-30-1 eb IIC T4 Gb
Ex 60079-30-1 tb IIIC T130°C Db
Ex 60079-30-1 eb mb IIC T4 Gb
Ex 60079-30-1 mb tb IIIC T130°C Db
Tmin –60°C
Ex tb IIIC T* Db X
Zone when installed with
E-20
cCSAus Certificate 1333271
US: Class I Zone 1 AEx eb IIC T6 Gb
Zone 21 AEx tb IIIC T85°C Db
Canada: Ex 60079-30-1 IIC T6 Gb
Ex 60079-30-1 IIIC T85°C Db
cCSAus Certificate 1333271
US: Class I Zone 1 AEx eb IIC T4 Gb
Zone 21 AEx tb IIIC T135°C Db
Canada: Ex 60079-30-1 IIC T4 Gb
Ex 60079-30-1 IIIC T135°C Db