Operation

General operation

If the pressing tool is not used for 30 seconds, it will switch to idle state. No LED is lit. Tapping
the start button will reactivate the device from idle state. The device is ready for operation; the
green LED lights up.
Inserting Geberit pressing
attachments
Pressing attachments are pressing jaws,
pressing collars and adapter jaws.
Observe the user manuals of the
Geberit pressing attachments. Check
the pressing attachments according
to the safety chapter.
1
Push in both release buttons on the
rechargeable battery and pull it out.
2
Pull out the retaining pin.
18014400405810571-1 © 12-2018
968.403.00.0 (00)
3
Insert the pressing attachment into
the pressing tool.
4
Push the retaining pin in until the
stop position is reached.