INCIDENTS AND SOLUTIONS TABLE
SYMPTOM
• Monitor does not enter in
programming mode.
• Monitor autoswitch-on does not
work.
• Monitor does not enter in
programming mode.
• Autoswitch-on does work.
• No call tone, but panel monitoring.
• When calling from panel, there is
no audio and the monitor emits a
continuous beep.
• Audio very weak, or feedback
that cannot be eliminated with the
audio adjust potentiometers.
• Door release does not work
properly.
POWER SUPPLY (LEDs)
ON
On LED
On LED + OVERLOAD blinking indicates short circuit.
Pag 32
- Negative section. Increase.
- Distance between panel and monitor. Increase section
or add additional power supply.
- Power supply location. Maximum distance to panel: 30 metres/
90 feet. Increase section or add additional power supply.
- Put the 10 KOhms Line end resistance.
- Distance between panel and monitor. Increase section
or add additional power supply.
- Check that the Panel is programmed as main.
- Check that the monitor is switched on.
- Check «L» wire.
- Monitor programmed wrongly. Program it again.
- Short circuit between «L» and «+».
- Short circuit between «L» and «-».
- Resistance 10 KOhms. There must only be 1 resistance
in the monitor furthest away.
- 12 Vdc door-opener with the 18 Vdc-1.5A power supply:
* Make sure you are using a 12 Vdc (direct current)
door-opener, max. 0.3 A.
* Increase the cross-section of the negative.
* Distance between panel and monitor. Increase the cross-
section or add additional power supply..
- 12 Vac door-opener with the 12 Vac-1A power supply:
* Make sure you are using a 12 Vac (alternating current) door-
opener, max. 0.8 A.
Led indicator maximum current exceeded.
POINTS TO CHECK
OVERLOAD