XXVI
www.azolgas.com
MOUNTING GUIDELINES
MOUNT TYPE A
ENG UPPER ROUND GROOVE FLANGE
DEU BUNDFLANSCH
FRA COLLERETTE POUR GORGE RONDE SUPÉRIEURE
ITA
FLANGIA PER SCANALATURA ROTONDA SUPERIORE
ESP BRIDA PARA CAJERA SUPERIOR REDONDA
POR FLANGE PARA O SULCO REDONDO SUPERIOR
Ø<32
ØB
When using mount type A into a bored pocket, the
bored pocket diameter (B) should not exceed 1mm
larger than the gas spring body diameter 32 mm and
not exceed 2 mm larger than gas spring body diameter
> 32 mm.
When using CS gas springs series we recommend the
base to be supported at all the times, a flat surface
against the base is always required.
Service in Motion
Ø>32
+1.0
+0.5
Do not use mounts type A when the mounting screws
have to support the full compression force of the gas
spring.
+2.0
ØB
+0.5
Following the mounting guidelines, mounts type A are
intended to be used both vertically right and upside
down.
!