XXX
www.azolgas.com
MOUNTING GUIDELINES
MOUNT TYPE C
ENG LOWER SQUARE GROOVE FLANGE
DEU FUSSFLANSCH
FRA FLASQUE-BRIDE POUR GORGE CARRÉE INFÉRIEURE
ITA
SEMI-FLANGIA PER SCANALATURA QUADRATA INFERIORE
ESP BRIDA PARA CAJERA INFERIOR CUADRADA
POR FLANGE PARA O SULCO QUADRADO INFERIOR
Following the mounting guidelines, mounts type C are
intended to be used vertically right.
THREAD LENGTH
The screws must keep a thread length of:
-thread diameter x1,5 if fixed in steel
-thread diameter x2 if fixed in casting
Service in Motion
Steel = min. 1,5 x D
Casting = min. 2 x D
azolgas@azolgas.com
!
When using mounts type C the base must be supported
at all the times to avoid full compression force of the
gas spring being transferred through the mounting
screws.
Mounting gas springs by using mount type C it is not
recommended when gas springs are upside down.