XXVIII
www.azolgas.com
MOUNTING GUIDELINES
MOUNT TYPE B
ENG BOTTOM MOUNT PLATE
DEU BODENBEFESTIGUNGSPLATTE
FRA PLAQUE FIXATION INFÉRIEURE
ITA
BASE INFERIORE DI FISSAGGIO
ESP BASE INFERIOR DE FIJACIÓN
POR PLACA INFERIOR DA MONTAGEM
Following the mounting guidelines, mounts type B are intended to be used both vertically right and upside down.
D
E
Min. thread length
(1 x D)
When mounting gas springs upside down by mounts B it is important to follow the instructions about quality of
screws, thread length, safety washers and torque.
Use thread locking if the gas spring base threads length (E) are < thread diameter (D), for example CW series.
Service in Motion
azolgas@azolgas.com
!
When using mounts type B the base must be supported
at all the times to avoid full compression force of the
gas spring being transferred through the mounting
screws.
D
E
Min. thread length
(1 x D)
Tel. +34 945290010
!
!