Care and maintenance

DANGER
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
Prior to all work on the appliance, switch off
the appliance and pull the power plug.
Note:
Used oil must only be disposed of by the
designated collection points. Please turn in
used oil there. Polluting the environment
with used oil is prosecutable.
Safety inspection/ maintenance
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
Before each use
 Check connection cable for damages
(risk of electrical shock); get the dam-
aged connection cable replaced imme-
diately by an authorised customer ser-
vice person/ electrician.
 Check the high pressure hose for dam-
ages (risk of bursting).
Please arrange for the immediate ex-
change of a damaged high-pressure
hose.
 Check appliance (pump) for leaks.
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.
 Check oil level Please contact Custom-
er Service immediately if the oil is milky
(water in oil).
 Clean the fine filter.
Unpressurize the appliance.
Unscrew lid with filter.
Clean the filter with clean water or com-
pressed air.
Reinstall in reverse sequence.
 Clean filter at the detergent suck hose.
18
contract
Weekly
Every 500 operating hours, at least
 Have the maintenance of the device
performed by the customer service.
 Oil change.
Oil change
Note:
See "Specifications" for oil volume and
type.
 Turn out the oil drain screw at the front
on the motor casing.
 Drain the oil in a collection basin.
 Screw in the oil drain screw.
 Fill in new oil slowly; air bubbles should
go out.
 Attach the lid of the oil container.
 Fasten the device hood.

Troubleshooting

DANGER
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
– Prior to all work on the appliance,
switch off the appliance and pull the
power plug.
– Get the electrical components checked
and repaired only by authorised cus-
tomer service persons.
– Contact an authorised customer service
person in case of problems not men-
tioned in this chapter or if you are in
doubt or when you have been explicitly
asked to do so.
Appliance is not running
 Check connection cable for damages.
 Call Customer Service in case of elec-
trical defects.
Pressure does not build up in the
 Install the high pressure nozzle.
 Clean/ replace nozzle.
 Clean the fine filter; replace it, if neces-
sary.
 Deaerate the appliance (see "Start-up")