10
PRESSURE SENSITIVE LC DISPLAY WITH ILLUMINATION
8
Thanks to the pressure-sensitive LC display, the device can be operated directly from the display
(glove-compatible). The LCD display shows the currently activated mode (main display), the menu
items in the selection menu and the numerical value or operating status in certain menu items. If
there is no control signal to the device, the display starts flashing; the flashing stops as soon as a
control signal is present (DMX and slave operation, ArtNet and sACN).
TOUCH-SENSITIVE CONTROLS
9
BACK – Press BACK (repeatedly) to move up one level in the menu structure to the main display.
and
– Select the individual menu items in the main menu (DMX address, operating mode,
etc.) and in the submenus. ENTER – Starting from the main display, press ENTER to enter the
main menu. In the main menu, press ENTER to access the menu level in which values can be
changed. You can also confirm value changes by pressing ENTER.
panel to change the value in a menu item, such as the DMX address, as desired.
USB INTERFACE
10
USB interface for updating the device firmware. In the Service menu, set the status for USB
update to ON. When available, download the latest firmware from the product page at www.
cameolight.com, unzip it and copy the files to a folder without special characters on a USB stick.
Disconnect the Moving Head from the mains and all input connections (DMX / Ethernet), connect
the USB stick to the USB interface and reconnect the Moving Head to the mains. The USB stick is
automatically recognised and shown in the display. Now navigate to the corresponding folder on
the USB stick and confirm with ON. The update procedure begins. Do not remove the USB stick or
disconnect the Moving Head from the mains during the update procedure. If updates are required
for several components, the procedure must be carried out individually for all updates.
The battery-powered display can be activated, even if the device is not connected to the mains. To
do this, press and hold BACK for approximately 4 seconds. You can now access device information
to change and save system settings without mains connection. External control of the spotlight is
not activated in this case. For this reason, the display shows that there is no DMX signal even if a
DMX signal is present at the device.
12
8
and
9
– Use the control