For cyclical switch commands the switching on time is set by logical "OR" of programs of all types. A fixed cycle of ON and OFF time then operates within those limits.
The cycle always starts with the ON time. The cycle duration and the ON time within the cycle are the same length for all switching times. The cycle duration and the
ON time can be set independently in one-second increments. If the switching time is shorter than the cycle duration, the cycle will be shortened accordingly. The ON
time will remain unchanged. If the switching time is actually shorter than the ON time, the ON time will be shortened accordingly.
15:00:00
Relais Channel 2
Cell disposal
Warning: Elektrical shock - Disconnect all power from the device
before dismantling the module and replacing the battery.
Always use a Li cell type battery (LiMnO2) CR2477, 3V high