Step B1: Preprogramming the Somfy io-homecontrol
This guide describes set-up using a Somfy Smoove io type io-homecontrol
Position the roller shutter at its half-way position.
1)
On the wired control point, press three times
2)
 and press once on
on
forth movement of the roller shutter:
The radio is activated and the drive is in
programming mode.
The drive remains in programming mode for ≈ 10 min.
On the io-homecontrol
3)
Λ
V
both
and
at the same time:
The roller shutter moves back and forth:
the  control  point has been preprogrammed in
the drive.
The rotation direction of the drive self-adjusts automatically during the first few cycles.
During the first few movements, the  
without the need for any settings, after maximum 2 complete cycles, from stop to stop).
For a roller shutter less than 0.5 m² (0.6 m x 0.7 m), see chapter Questions on S&SO-RS100
io HYBRID?
a
Step B2 
: Setting / resetting of end limits in manual mode with the io-homecontrol
control point
This procedure is only applicable to roller shutters without rigid links and with stops.
From 3), in set mode:
The roller shutter moves more slowly during the first few seconds of movement.
Position the roller shutter at its half-way position.
1)
On the io-homecontrol
2)
V
simultaneously, for ≈ 5 s, until there is back and
forth movement by the roller shutter.
The drive is in set mode.
The drive remains in set mode for ≈ 10 min.
Move the roller shutter to the desired upper (or lower)
3)
end limit.
my,
Press
for ≈ 2 s, until there is back and forth
4)
movement by the roller shutter.
The setting for the first end limit is confirmed.
Move the roller shutter to the desired lower (or upper)
5)
end limit.
my
Press
, for ≈ 2 s, until there are two back and
6)
forth movements by the roller shutter.
The setting for the second end limit is confirmed.
The settings for the end limits are programmed.
The drive enters programming mode for ≈ 2 min. if no io-homecontrol
programmed.
Copyright© 2014-2017 SOMFY ACTIVITES SA, Public Limited Company. All rights reserved.
until there is back and
control point, briefly press
®
Λ/V
orders may be inverted (they adjust automatically
control point, press
®
local control point
®
1)
2)
3)
0.5 s
Λ
and
1)
3)
5)
EN
local control point.
®
x 3
2.5 s
®
2)
5 s
4)
2 s
6)
2 s
x 2
control point is
®
57

Publicidad

Tabla de contenido
loading

Tabla de contenido