Safety Devices
Caution
Safety devices protect the user and must not
be modified or bypassed.
Power switch
The appliance switch prevents unintentional
operation of the appliance.
Lock trigger gun
This lock locks the lever of the trigger gun and
prevents the inadvertent start of the appli-
ance.
Overflow valve with pressure switch
The overflow valve prevents the permissible
working pressure from being exceeded.
If the lever on the trigger gun is released the
pressure switch turns off the pump, the high-
pressure jet ist stopped. If the lever is pulled
the pump is turned on again.
Operation
Description of the Appliance
When unpacking the product, make sure that
no accessories are missing and that none of
the package contents have been damaged. If
you detect any transport damages please
contact your dealer.
Illustrations on Page 2
1
Connection for water supply with filter
2
Coupling element for water connection
3
High pressure connection
4
Appliance switch "0/OFF"/ „I/ON"
5
Detergent Tank
6
Suction hose for detergent
7
Storage for trigger gun
8
Transport handle
9
Storage for accessories
10 Hose drum
11 Mains cable with mains plug
12 Trigger gun
13 Lock trigger gun
14 High pressure hose
15 Spray lance with pressure regulation
(Vario Power)
16 Spray lance with Dirtblaster
All manuals and user guides at all-guides.com
Special accessories
Special accessories expand the possibilities
of using your appliance. Please contact your
KÄRCHER dealer for further information.
Before Startup
Illustration
Mount loose parts delivered with appli-
ance prior to start-up.
Illustration
Push the high pressure hose into the trig-
ger gun until it locks audibly.
Note: Make sure the connection nipple is
aligned correctly.
Check the secure connection by pulling on
the high-pressure hose.
Water supply
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is consid-
ered non-drinkable.
Note: Impurities in the water can damage the
high-pressure pump and accessories. For
protection, the use of the KÄRCHER water fil-
ter (optional accessory, order no. 4.730-059)
is recommended.
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/techni-
cal data.
Use a fibre-reinforced water hose (not in-
cluded) with a standard coupling. (Mini-
mum diameter 1/2 inch (13 mm),
minimum length 7.5 m).
Illustration
Screw the coupling element (supplied) to
the water connection on the appliance.
Push the water supply hose onto the coupling
unit, then connect it to the water supply.
Drawing in water from open reservoirs
This high-pressure cleaner is suited to work
with the KÄRCHER suction hose with back-
flow valve (Optional accessory, order no.
4.440-238) to draw in surface water, e.g. from
5
Deutsch