6
Care and Maintenance
RODRUM VarioClean:
Pull out the mains power plug before starting any servicing or maintenance!
The machine is maintenance-free except for the feed unit.
Clean and grease the feed unit regularly and check it for damage. The ball bearings can be re-
placed if necessary.
The device should be handled carefully and cleaned regularly.
The spirals and tools should be cleaned and preserved after every use. We recommend using
our "ROWONAL" special care product.
All of the servicing, maintaining and repair work is only be undertaken by instructed
specialist personnel!
Charger:
Repairs to the charger must only be carried out by qualified electricians.
If the mains connection cable of this tool is damaged, in order to prevent endangering personnel
and property it must be replaced by the manufacturer, or the Customer Service of the manufac-
turer, or a similarly qualified person.
6.1
Inserting new spirals
Remove the spiral drum (see Section 5.10).
Pull the spiral fully out of the drum by hand.
First introduce a new spiral with the kinked end into the drum and push in the spiral up to
about 30 cm.
Re-insert the spiral drum (see Section 5.10).
7
Troubleshooting
Symptom
LEDs in the frame flash long
LEDs in the frame flash briefly
The machine does not start
The machine does not start
No feed
8
Accessories
You can find suitable accessories in the main catalog or at www.rothenberger.com
24
Possible Reason
Low battery charge
Battery is drained
Motor temperature is too
high
Battery temperature is too
high
Battery has not been re-
charged
Foot switch / compressed air
hose is defective
Spiral defective
Ball bearing in the feed unit
is defective
ENGLISH
Solution
Charge the battery.
Charge the battery.
Let the motor cool down
Let the battery cool down
Charge the battery.
Contact our customer
service department
Replace the spiral
Contact our customer
service department