6.3.2 Setting parameter menu

Touch
to eneter on menu
Symbol
Function
Touch to go back
Touch to go move forward to next screen
Touch to view the thresholds of the analogue out-
put of the dew point "A6 / A8",
Touch to confi gure: the unit of measure; local / re-
mote start and alarm signaling ",
Touch to confi gure the drain
Touch to see the working hours and time of the
next scheduled maintenance.
Touch to confi gure the dryer
Touch to reset the alarm.
English
Probes
Touch
to enter
these parameters are available for reading / writing, it is possible to
change: the high dew point warning threshold and the delay
To modify the parameter, touch the value, as shown in the fi gure.
The keyboard used to dial the new desired value appears
PSE 120-350
Confi guration
Touch
to enter
touch
to go ahead
these parameters are all adjustable: unit of measure (°C or °F); local or
remote start; alarm warning and restoring the default parameters.
Y
To manage REMOTE OFF mode, remove the bridge between
terminals: 87-92 and connect the remote start/stop switch (to be
provided for by the customer).
To modify parameter, touch the value, as shown in the fi gure.
Choose your options.
(eg "°C or °F", or "Local on or rOFF")
7/12