MAINTENANCE & ADJUSTMENTS
The 0
(blade vertical) position can be adjusted.
0
WARNING: The battery must be removed from the machine
when attempting this procedure.
To check 0
position:
0
• Set the blade to the 0
position with the tilting mechanism
0
against its stop.
• Check the blade against the sole plate using an engineers
precision square (not supplied). Take care to avoid the TCT tips
of the teeth. The blade should be at exactly 90
Note: The lower blade guard should be rotated (manually) up
into the upper blade guard. This will help accurate positioning
of the engineers square and thus aid the checking process.
If adjustment is required:
Turn the adjustment screw (Fig. 16) clockwise or counter
clockwise using a Hex Key (not supplied) until the blade is at
exactly 90
to the sole plate.
0
www.evolutionpowertools.com
Fig. 16
to sole plate.
0
18