Installation and connection
Vitronic 11 W
• It is not necessary to remove the unit head in order to fasten the casing on the ground.
• The UVC lamp has been pre-installed at the factory.
Vitronic 18 W, 24 W, 36 W, 55 W
• It is necessary to remove the unit head before fastening the casing on the ground.
(→ Dismantling the unit head)
• The UVC lamp was not pre-installed at the factory. Insert the UVC lamp in the unit head before
reinstalling the unit head. (→ Inserting the UVC lamp)
Dismantling the unit head
Vitronic 18 W, 24 W, 36 W, 55 W
CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
Never operate the UVC lamp outside out the casing or in a damaged casing.
Disconnect the unit from the power grid before starting any maintenance work or before re-
placing the UVC lamp.
CAUTION
The quartz glass and UVC lamp could break and cause cuts.
Act with caution when performing work on the UVC clarifier in order to avoid cuts.
Avoid shocks, impacts and abrupt movements to prevent the glass from breaking.
For safety reasons, the UVC lamp can only be turned on when the UVC clarifier is properly
installed in the unit.
B
How to proceed:
• Push down the snap-fit hook, then turn the unit head counter-clockwise up to the stop and
carefully pull the unit head out of the casing.
Installing the unit
C, D
• Install the unit at least 2 m from the edge of the pond.
• Only install the unit in the permitted positions. This ensures fault-free operation.
• Allow sufficient space for carrying out maintenance work.
EN
17