b. Items to be checked at time of delivery
I
e t
m
s
o t
b
e
c
h
e
c
e k
d
Are you sure the control box lid, air filter, air inlet grille, and
air outlet grille are mounted?
Did you explain about operations while showing the
operation manual to your customer?
Did you deliver the operation manual along with the
installation manual to the customer?
Did you explain the customer the handling and cleaning
methods of the field supplies (e.g., the air filter, air inlet
grilles, and air outlet grille)?
Did you deliver instruction manual, if any, for the field
supplies to the customer?
c. Points for explanation about operations
The items with
WARNING and
manual are the items pertaining to possibilities for bodily injury and
material damage in addition to the general usage of the product.
Accordingly, it is necessary that you make a full explanation about
the described contents and also ask your customers to read the
operation manual.
2-4 NOTE TO INSTALLER
• Be sure to instruct customers how to properly operate the
unit (especially cleaning filters, operating different functions,
and adjusting the temperature) by having them carry out
operations themselves while looking at the manual.

3. SELECTING INSTALLATION SITE

〈Hold the hanging brackets in the case of moving the
indoor and outdoor units at the time of and after opening
the packages. Do not impose undue force on other parts,
such as the refrigerant piping, drain piping, or flanges,
in particular.〉
〈Add heat insulation material to the indoor unit if the
temperature above the ceiling is likely to exceed 30°C and
a relative humidity of 80%.〉
〈 Make sure that the insulation material is made of glass wool
or polyethylene foam, has a minimum thickness of 10 mm,
and can be accommodated in the opening on the ceiling. 〉
(1) Select an installation site where the following conditions are
fulfilled and that meets with your customer's approval.
• A place where cool (warm) air is delivered to the entire
room.
• Where nothing blocks the air passage.
• Where condensate can be properly drained.
• If supporting structural members are not strong enough
to take the unit's weight, the unit could fall out of place
abd cause serious injury.
• Where the false ceiling is not noticeably on an incline.
• Where there is no risk of flammable gas leakage.
• Where sufficient clearance for maintenance and service
can be ensured. (Refer to Fig. 2-1)
• Where piping between indoor and outdoor units is
possible within the allowable limit. (Refer to the
installation manual of the outdoor unit.)
CAUTION
• Install the indoor and outdoor units, power supply wiring and
connecting wires at least 1 meter away from televisions or
radios in order to prevent image interference or noise.
(Depending on the radio waves, a distance of 1 meter may
not be sufficient enough to eliminate the noise.)
• In the case of the installation of a wireless remote controller,
the transmission distance of the wireless remote controller
may be shortened if the room has a fluorescent light of
electronic lighting type (i.e., an inverter or rapid-start
fluorescent light). Keep the distance between the receiver
and the fluorescent light as far as possible.
4
C
h
e
k c
CAUTION marks in the operation
(2) Use hanging bolts to install the indoor unit. Check that the
place of installation withstands the weight of the indoor unit.
Secure the hanging bolts with proper beams if necessary.
Ceiling
Floor surface
• The H1 dimension indicates the
height of the product.
• Determine the H2 dimension by
maintaining a downward slope of
at least 1/100 as specified in
"7. DRAIN PIPING WORK".

4. PREPARATIONS BEFORE INSTALLATION

(1) Check the positional relationship between the ceiling
opening hole and the hanging bolt of the unit.
• For the maintenance, inspection, and other servicing
purposes of the control box and drain pump, prepare one
of the following service spaces.
1. Inspection hatch 1 (450 × 450) for the control box and
a minimum space of 300 mm for the lower part of the
product. (Refer to Fig. 2-2)
2. Inspection hatch 1 (450 × 450) for the control box and
inspection hatch 2 for the lower part of the product
(see axial direction view A-1). (Refer to Fig. 2-3)
3. Inspection hatch 3 for the lower part of the product
and the lower part of the control box (see axial
direction view A-2). (Refer to Fig. 2-3)
Case 1
Ceiling
• FXMQ50 • 63 • 80 • 100 • 125 • 140 type
(Hanging bolt pitch)
Air outlet
Inspection hatch 2
(450 x 450)
(For remove drain pan and
change part)
* In case can work at space
of below product, inspection
hatch 2 is unnecessary.
(length: mm)
Min. 700 (service space)
[Required installation place]
The dimensions indicate the
minimum required space of
installation.
Fig. 2-1
Control box
Inspection hatch
700
Inspection hatch 1
631
(450×450)
Control box
Air inlet
Bottom of unit
Hanging bolt (× 4)
English