3. Inspecting the carbon brushes (Fig. 5)
The motor employs carbon brushes which are consumable parts. Replace the carbon
brush with a new one when it becomes worn to its wear limit. Always keep carbon
brushes clean and ensure that they slide freely within the brush holders.
CAUTION: Using this portable grinder with a carbon
brush which is worn in excess of the wear
limit will damage the motor.
NOTE: Use HITACHI carbon brush No. 21 indicated in
Fig. 5.
4. Replacing carbon brushes
Remove the brush caps (Fig. 1) with a slotted
screwdriver. The carbon brushes can then be easily
removed.

SERVICE AND REPAIRS

All quality power tools will eventually require servicing or replacement of parts because of
wear from normal use. To assure that only genuine replacement parts will be used, all
service and repairs must be performed by a HITACHI AUTHORIZED SERVICE CENTER, ONLY.
NOTE: Specifications are subject to change without any obligation on the part of the
HITACHI.
16
All manuals and user guides at all-guides.com
No. of Carbon Brush
Wear Limit
21
0.20" (5 mm)
0.47" (12 mm)