Important Information; Conformity With European Regulations - TESY HPWH 2.1 260 U02 S Instrucciones De Uso Y Mantenimiento

Bomba de calor para agua caliente sanitaria
Ocultar thumbs Ver también para HPWH 2.1 260 U02 S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

(EN 16147:2017 - A14/W55)
(EN 16147:2017 - A7/W55)
(EN 16147:2017 – A2/W55)
Maximal heat output (Summer condition)
Electrical data
Power supply
Frequency
Degree of protection
HP maximum power consumption
Electric heating element power
Maximum current of appliance
Max. starting current of heat pump
Required overload protections
Internal thermal protection
Operating conditions
Min.÷ max temperature heat pump air intake
(90% R.H.)
Min. ÷ max temperature installation site
Working temperature
Reference DHW temperature
(EN 16147:2017)
Max. settable water temperature [with E-
heater]
(EN 16147:2017)
Compressor
Compressor protection
Automatic safety pressure switch (high)
Automatic safety pressure switch (low)
Fan
Available external pressure of heat pump
Ejection outlet diameter
Nominal air capacity
Motor protection
Condenser
Refrigerant
Refrigerant charge
Global warming potential of the refrigerant
CO
equivalent (CO2e)
2
Defrosting
Sound emission data; EN12102:2013
Sound power Lw(A) indoor
Automatic anti-Legionella cycle
Water storage tank
Descriptions
Water storage capacity
Solar heat exchanger surface
Solar heat exchanger volume
Corrosion protection
Thermal insulation
Maximum working pressure – storage tank
Transport weight
*The output data refers to new appliances with clean heat exchangers!!!
4.

IMPORTANT INFORMATION

4.1. Conformity with European regulations

The EVHP heat pump is a device intended for domestic use in conformity with the following European directives:
2012/19/ЕU Directive on waste electrical and electronic equipment (WEEE);
1.33
1.20
0.98
kW
2.305
V
Hz
kW
kW
A
A
A
16A T fuse/ 16A automatic switch, characteristic C (to be
expected during installation on power supply systems)
Safety thermostat with manual reset
°C
°C
°C
°C
Thermal circuit breaker with automatic reset
MPa
MPa
Pa
mm
3
m
/h
Internal thermal circuit breaker with automatic reset
Aluminium; wrapped externally, not in contact with water
g
t
dB(A)
HP2.1 260S
l
251
2
m
1.2
l
7.5
Bar
Kg
128
10
1.33
1.16
1.20
1.05
0.98
0.88
2.305
2.305
1/N/220-240
50
IPX4
0.663+1,500 (e-heater) = 2,163
1.5
3.1+6.5 (e-heater) = 9.6
13.5
-10 ÷ 43
4 ÷ 40
55
65 [75]
Rotary
2.5
0.1
Centrifugal
77
160
315 (98 Pa)
R134a
880
1430
1287
Active with "4-way valve"
53
YES
HP2.1 260
HP 2.1 200S
260
194
n.a.
1.0
n.a.
5.8
Mg anode Ø33x400 mm
50 mm rigid PU
8
110
121
1.16
1.05
0.88
2.305
HP2.1 200
202
n.a.
n.a.
105