ECODESIGN REQUIREMENTS FOR SOLID FUEL BOILERS
ACCORDING TO COMMISSION REGULATION (EU) 2015/1189
AND ECOLABEL REQUIREMENTS FOR SOLID FUEL BOILERS
ACCORDING TO COMMISSION REGULATION (EU) 2015/1187
The present document cancels and supersedes document issued November 29, 2018.
ITALIANA CAMINI – TERMIKA2 24
Stoking mode: Automatic: it is recommended that the boiler be operated with a hot water storage tank of a
volume of at least 480 litres (**)
Condensing boiler: no
Solid fuel cogeneration boiler: no
Fuel
Log wood, moisture content ≤ 25 %
Chipped wood, moisture content 15-35 %
Chipped wood, moisture content > 35 %
Compressed wood in the form of pellets
or briquettes
Sawdust, moisture content ≤ 50 %
Other woody biomass
Non-woody biomass
Bituminous coal
Brown coal (including briquettes)
Coke
Anthracite
Blended fossil fuel briquettes
Other fossil fuel
Blended biomass (30-70 %)/fossil fuel
briquettes
Other blend of biomass and fossil fuel
(**) Tank volume = 20 x P
with P
indicated in kW
r
r
Characteristics when operating with the preferred fuel only:
Seasonal space heating energy efficiency ηs [%]: 84
ACTECO s.r.l.- Via Amman, 41 – 33084 CORDENONS (PN) – Tel. 0434 / 43675-541343-43171 – www.acteco.it
Energy efficiency index EEI: 124
Cap. Soc. € 78.000,00 i.v. – Iscr. Reg. Impr. n. 00218610939 – Cod. Fisc. e P.IVA 00218610939
Item
Symbol
Value
Useful heat output
24,0
At rated heat output
P
n
At [30 %/50 %] of
rated heat output, if
P
p
applicable
For solid fuel cogeneration boilers: Electrical
efficiency
At rated heat output
η
N.A.
el,n
Contact details
Name and address of the manufacturer or its authorized representative.
Tel. +39 02 937621
Manufacturer: EDILKAMIN SPA
www.edilkamin.it
mail@edilkamin.it
Issue date:
June 14, 2019
Head of Test Laboratory
Dr.ssa Claudia Marcuzzi
Firmato
digitalmente da
MARCUZZI
Inclusa nell'albo dei laboratori altamente qualificati, autorizzati
dal Ministero dell'Università e della Ricerca Scientifica e
Tecnologica ex art. 4 legge n. 46/82 (D.M. 25 maggio 1990)
DATOS TÉCNICOS
Combination boiler: no
Preferred
Other
η
fuel (only
suitable
s
[%]:
one):
fuel(s):
no
no
no
no
no
no
yes
no
84
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
Inclusa nell'albo dei laboratori altamente qualificati, autorizzati
dal Ministero dell'Università e della Ricerca Scientifica e
Tecnologica ex art. 4 legge n. 46/82 (D.M. 25 maggio 1990)
no
no
Pag. 1 of 2
Unit
Item
Useful efficiency (GCV as received)
kW
At rated heat output
At [30 %/50 %] of
6,0
kW
rated heat output, if
applicable
Auxiliary electricity consumption
At rated heat output
At [30 %/50 %] of
rated heat output, if
applicable
%
Of incorporated secondary
emission abatement
equipment, if applicable
In standby mode
Via Mascagni 7
20020 Lainate (MI) – ITALY
Seasonal space heating
emissions
PM
OGC
CO
NOx
3
mg/m
at 10%O
2
16
4
288
121
Symbol
Value
Unit
86,9
η
%
n
88.2
η
%
p
el
0,090
kW
max
el
0,020
kW
min
N.A.
kW
0,004
P
kW
SB
®