The Vibration Total Value quoted in these instructions and the quoted noise emission values
were measured according to standardized measurement procedures and can be used to com-
pare one electric power tool with another. They can also be used to make an initial estimate of
the loading.
The quoted vibration and noise emissions can vary during actual use of the electric
power tool dependent on the way in which the electric power tool is used, in particular
what type of workpiece is being processed. Establish additional safety measures to
protect the operator which are based upon an estimate of the vibration loading during the actual
usage conditions (in doing so taking account of parts of the operating cycle, for example times in
which the electric power tool is switched and those in which it is switched on but not running
under load).
3
Scope of delivery
- Pipe cleaning machine
- Guide tube
- Operating manual
4
Power connection
Connect only to the single-phase alternating current indicated on the rating plate. Connect only
to sockets with protective contacts. The machine must be operated only through a ground fault
circuit with max. 10 - 30 mA rated leakage current.
Always perform the operational test before starting up the device. If there is a repeated failure,
have the connected device inspected.
Please keep in mind that this device cannot replace fundamental safety precautions. To prevent
life-threatening hazards, be sure to use electrical devices only as intended.
Reliable personal protection against electric shock. Fault currents are recognized in a fraction of
a second, and the current supply is immediately interrupted. The risk to humans and animals is
drastically reduced.
- Never use the electric tool without a PRCD.
- The plug or electrical cord should be replaced only by the manufacturer of the electric tool or
by its repair service.
- Keep water away from electrical parts of the electric tool and from people in the work area.
4.1
Putting the PRCD switch into operation
Only suitable for AC current! Note the mains network voltage!
Perform the following test procedure on the PRCD switch before every putting into operation of
the device:
1. Connect the PRCD plug connector with the socket.
2. Press on RESET. The indicator switches to ON.
3. Pull the plug connector out of the socket. The display switches itself off.
4. Repeat 1. and 2.
5. Press on TEST. The indicator switches itself off.
6. Press on RESET to switch the device on.
These protective device protect against faults in the attached device, not against
such faults in the preceding plant!
5
Function of the Unit
5.1
Use standard spirals
The possible spiral diameters and spiral lengths that may be used are set out in the section enti-
tled Technical data.
ENGLISH
(A)
15