4. Electrical work
Manual vane angle
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
Maintenance menu
Auto descending panel
Manual vane angle
3D i-See sensor
Main menu:
Cursor
F1
F2
F3
F4
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Address
Check
F1
F2
F3
F4
Manual vane angle
Select:
Outlet
Angle
F1
F2
F3
F4
Manual vane angle
Setting
1 Select "Maintenance" from the Main
menu, and press the [SELECT]
button.
2 Select "Manual vane angle" with
the [F1] or [F2] button, and press
the [SELECT] button.
3 Select the "M-NET address" for
the units to whose vanes are to be
fixed, with the [F2] or [F3] button,
and press the [SELECT] button.
Press the [F4] button to confirm the
unit.
The vane of only the target indoor
unit is pointing downward.
4 The current vane setting will appear.
Select the desired outlets from 1
through 4 with the [F1] or [F2] button.
• Outlet: "1", "2", "3", "4" and "1, 2, 3,
4, (all outlets)"
Press the [F3] or [F4] button to go
through the option in the order of
"No setting (reset)," "Step 1", "Step
2", "Step 3", "Step 4", "Step 5" and
"Draft reduction*".
Select the desired setting.
* Draft reduction
T h e a i r f l o w d i r e c t i o n f o r t h i s
setting is more horizontal than the
airflow direction for the "Step 1"
setting in order to reduce a drafty
feeling. The draft reduction can be
set for only 1 vane.
Vane setting
No setting
Step 1
Step 3
Step 4
Draft
All
reduction*
outlets
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being
transmitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
will be displayed the next time the unit
goes into operation.
Navigating through the screens
• To go back to the Main menu .........................[MENU] button
• To return to the previous screen ....................[RETURN] button
Confirmation procedure
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Address
Check
F1
F2
F3
F4
Manual vane angle
M-NET address
Function setting for unit
with vane fully open.
Return:
F1
F2
F3
F4
Manual vane angle
No communication
Check Unit state.
Return:
F1
F2
F3
F4
Step 2
Step 5
1 Select the "M-NET address" for
the units to whose vanes are to be
fixed, with the [F2] or [F3] button.
Press the [F4] button to confirm
the unit.
2 A fter pressing the [F4] button,
wait approximately 15 seconds,
and then check the current state
of the air conditioner.
→ The vane is pointing downward.
→ This air conditioner is displayed
on the remote controller.
→ All outlets are closed. → Press
the [RETURN] button and contin-
ue the operation from the begin-
ning.
→ The messages shown to the
left are displayed. → The target
device does not exist at this refrig-
erant address.
• Press the [RETURN] button to re-
turn to the initial screen.
3 Change the "M-NET address" to
the next number.
• Refer to step 1 to change the
"M-NET address" and continue
with the confirmation.
11