Disassembly And Disposal; Maintenance; Technical Specifications - SICK WTB4FP MultiSwitch Manual De Instrucciones

Ocultar thumbs Ver también para WTB4FP MultiSwitch:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
8

Disassembly and disposal

9

Maintenance

10

Technical specifications

Recommended sensing range for the best performance
Sensing range max.
Light spot size / distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Communication mode
8025665.1DTW /2022-02-14 | SICK
Subject to change without notice
LED/fault pattern
No object in beam path, no
output signal
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL
Cause
Test input (Test) is not con‐
nected properly
WTB4FP-xxxxx1
40 mm ... 140 mm
4 mm ... 220 mm
(Typ)
1)
Ø 5 mm (50 mm) (Typ) ,
Ø 4 mm (100 mm) (Typ)
DC 10 ... 30 V
2)
≤ 5 Vss
≤ 100 mA
25 mA
COM2
O P E R A T I N G I N S T R U C T I O N S | WTB4FP MultiSwitch
Measures
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
WTB4FP-xxxxx2
30 mm ... 60 mm
4 mm ... 100 mm (Typ)
Ø 2 mm (50 mm) (Typ)
DC 10 ... 30 V
2)
≤ 5 Vss
≤ 100 mA
25 mA
COM2
8
en
27

Publicidad

Tabla de contenido
loading

Tabla de contenido