3.2
Intended use
The DD 110W is an electrically powered diamond core drilling machine designed for hand‐held dry drilling
in masonry and for hand‐held wet drilling in concrete and mineral materials. Drilling in an upward direction in
wet-drilling mode is strictly prohibited.
Drilling into materials that produce electrically conductive dust (e.g. magnesium) is not permissible. Whenever
possible, use a mobile dust extractor suitable for the application.
To avoid injury, use only genuine Hilti core bits and DD 110W accessories.
Comply with the safety rules and operating instructions for the accessories used. Observe the information
printed in the operating instructions concerning operation, care and maintenance.
The tool is designed for professional use and may be operated, serviced and maintained only by trained,
authorized personnel. This personnel must be specifically informed about the possible hazards. The tool and
its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used not
as directed. Possible fields of use: construction site, workshop, renovation, conversion or new construction.
The tool may be operated only when connected to a power supply providing a voltage and frequency in
compliance with the information given on its rating plate.
Working with materials hazardous to the health (e.g. asbestos) is not permissible.
Modification of the tool is not permitted.
3.3
Items supplied
Power tool with side handle and chuck, operating instructions
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
3.4
TPS theft protection system (optional)
The product can be equipped with the optional TPS theft protection system. It can then be unlocked and
made ready for operation only through use of the corresponding TPS key.
4
Technical data
For rated voltage, rated current, frequency and/or input power, refer to the country-specific rating plate.
If the product is powered by a generator or transformer, the generator or transformer's power output must
be at least twice the rated input power shown on the rating plate of the product. The operating voltage of
the transformer or generator must always be within +5 % and -15 % of the rated voltage of the device.
Weight in accordance with EPTA procedure 01/2003
Weight
Speed
Dimensions (length x width x height)
Protection class
Permissible water supply pressure
Ambient temperature for operation
Storage temperature
4.1
Core bit diameter
Ø PCM core bits, dry
Ø HDM core bits, dry
Ø HWC core bits, wet
*351006*
351006
1st gear
2nd gear
1st gear
42 mm ... 162 mm
102 mm ... 162 mm
122 mm ... 132 mm
5.7 kg
5.7 kg
650 /min
1,380 /min
457 mm x 120 mm x
170 mm
I
≤ 6 bar
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
2nd gear
•/•
16 mm ... 87 mm
25 mm ... 112 mm
English