10-8
PROGRAMMING MENU
To enter the programming menu, press the select button for 10 sec. To scroll through the programming menu, turn the select
button, then press it to enter and change the parameters. To change the parameters, turn the select button, then press it to
confirm the data and return to the programming menu.
DISPLAY
Programming Dose No.1
The timer advances to +/- 0.05 sec.
Programming Dose No.2
The timer advances to +/- 0.05 sec.
Programming Dose No.3
The timer advances to +/- 0.05 sec. Dose No.3 can be disabled by turning the
select button anti-clockwise. The timer will display the wording OFF.
Continuous Dose Programming
The Continuous Dose can be enabled (ON) or disabled (OFF)
Dose counter P: partial T: total
To reset the partial counter data, press the selection button, turn it to select the
partial counter to be reset and press it again, holding it in for 10 seconds.
Settings
Press the selection button to go to the submenu.
Selecting the type of dosing
Standard: select the type of dose using the select button.
Push and Grind: select using the dosing button.
Fast program
The quick programming function can be enabled (ON) or disabled (OFF). To set the
fast programming function, see section 10-6-6.
Password
The Password prevents access to the programming
menu. To set the Password,
see chapter 10-6-7
Save: saves the Password Exit: exits without saving
Data
The software allows you to save three dates that can
be edited. To set the date
see chapter 10-6-8
Save: saves the date Exit: exits without saving
Software version
Return to main menu
EXIT
Press the select button to exit the programming menu.
FUNCTION