RE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be
flexible during the movement and must move without frictions.
Before the installation of PLUS, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in
Fig. 1.
Gate features must be uniformed with the standards and laws in
force. The gate can be automated only if it is in a good condition and
its conditions comply with the EN 12604 norm.
- The gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in
accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by
installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical
stops are not safe enough.
F
IXING THE ACTUATOR ATTACHMENT TO THE COLUMN
To obtain a correct movement of the leaf gate it is necessary to respect
the measures (to see the TABLES of the measures).
C
OLUMN ATTACHMENT FOR PLUS OPERATOR
If the column is in iron, the attack can be screwed directly using four
metric screws M8.
If the column is in concrete, the attack can be fixed with four expansion
screws Ø 8 mm (Fig. 2-3).
In the case you have a wall parallel with the open gate, you must
provide a niche in which to place the operator.
C
OLUMN ATTACHMENT FOR PLUS L OPERATOR
To obtain a correct movement of the leaf gate it is necessary to respect
the measures.
If there is an iron pillar you can weld the attachment directly.
If there is a cement pillar, you can use the fixing plate as in Fig. 5 which
is fastened with 4 Fischer-screws of Ø 8 mm.
There is also the possibility to cement the attachment welding an
anchor at its base Fig. 6.
Naturally you have to respect predetermined fixing measures.
Afterwards you must weld the other actuator's attachment to the gate
(Fig. 8).
In the case you have a wall parallel with the open gate, you must
provide a niche in which to place the operator.
6-1624020 rev. 5 05/11/2007
All manuals and user guides at all-guides.com
Parts to install meeting the EN 12453 standard
COMMAND TYPE
Skilled persons
(out of public area*)
with manned operation
A
with visible impulses
C or D
(e.g. sensor)
with not visible impulses
C or D
(e.g. remote controldevice)
automatic
C or D
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated)
B: Key selector with manned operation
C: Adjustable power of the motor
D: Photocells (To apply every 60÷70 cm for all the height of the column of the gate
up to a maximum of 2,5 m - EN 12445 point 7.3.2.1)
2
4
6
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
B
non possibile
C or D
C or D
C or D
C or D
C or D
C or D
3
5
7