ECHANICAL STOPPER ADJUSTMENT
To adjust the stoppers you have to follow the scheme (Fig. 12).
To set the opening limit it's enough to fix the stopper (A) in the needed
position by tightening the 8mA screw with a n.13 key.
To obtain the desired closing limit you must adjust the stopper (B)
(OPTIONAL) ) in the needed position and tighten it as for stopper (A).
E
LECTRICAL SAFETY DEVICES
The installation must be installed according to the current regulations
and laws.
For connections and technical data of accessories refer to the
appropriate booklets.
C
ONNECTION TO THE POWER SUPPLY
In single-phase PLUS units, terminals 1-2-3 of the motor connector
must be connected respectively to terminals OPEN-CLOSE-
COMMON of the control panel.
W
ARNING!
The length of connection cables from the motors to the control panel
unit must not exceed 15 m. The wire section of the motor power supply
must be 2.5 mm
, whilst that of the accessories must be 0,75 mm
2
F
ORCE ADJUSTMENT
Single-phase PLUS require a electronic control panel equipped with
electronic force regulator.
M
AINTENANCE
To be undertaken only by specialized staff after disconnecting power
supply.
Lubricate the hinges and check the oil level and thrust force generated
by the operator on the gate once a year.
Lubricate the nut screw with silicon grease every two years.
6-1624020 rev. 5 05/11/2007