CONTROL PANEL FEATURES
1
2
1. Output Ready Indicator LED (Green): Illuminates when
the generator is operating normally and indicates the
generator is producing electrical power at the receptacles.
2.
Overload Indicator LED (Red):
generator is overloaded which means the generator's
wattage / amperage capacity has been exceeded by
connected electrical devices or by a power surge.When
this occurs, the Output Ready Indicator LED will go off.
The engine will continue to run, but the red Overload
Indicator LED will stay on, and power will no longer be
supplied to connected electrical devices. To rest the
generator:Remove all applied loads and stop the engine.
Review for any faulty or shorted connections.
Start the generator and reconnect electrical devices
sequentially, allowing the generator to stabilize after each
device is connected. Make sure the total wattage of
connected electric devices are not exceeding recommend-
ed rated output power.
3. Oil Warning Indicator LED (Red):
when the engine oil level falls below the safe operating
level and the generator will automatically shut off the
engine. The engine will not start until the proper
amount of oil is in the crankcase.
4. Engine Control Switch: To start engine manually,
flip the switch to RUN (I)
recoil starter. To start engine with electric start,
press and hold the switch on the START (II)
NOTE: Total power drawn from all outlets must not exceed the nameplate rating.
3
4
Illuminates when the
Illuminates
position and pull
5 6
7
13
12
position and the engine will crank and attempts to
start. When the engine starts, release the switch
to the RUN (I)
5. Low Idle Switch:
consumption and noise by adjusting the engine speed
to the minimum required for the current load.
6. Parallel Operation Outlets: Connect two AIPOWER
inverter generators through a parallel connection kit for a
higher output.
7. 5V DC, USB Outlet:
amps.
8. Circuit Breaker (AC): Protects the generator against
electrical overloads.
9. Main Circuit Breaker: Protects the generator against
electrical overloads.
10. 120/240V AC, 30A Twist Lock, Single Phase,
60 Hz Outlet (NEMA L14-30R):
Volt or 240 Volt output up to 30 amps.
11. 120V AC, 20A Duplex, GFCI, Single Phase, 60 Hz Outlets
(5-20R):
Each outlet is capable of carrying a maximum of 20
amps on a single outlet or a combination of both outlets.
12. 120V AC, 30A Twist Lock outlet, single phase, 60 Hz
Outlet (NEMA L5-30R): This receptacle can provide 120 volt
output up to 30 amps.
13. Ground Terminal: The ground terminal is used to ground
the generator.