5.1

Permissible installation

Fig. 2: Permissible installation positions
5.2

Type key

Example: Yonos MAXO-D 32/0.5-11
Yonos MAXO
-D
-Z
32
0.5-11
5.3

Technical data

Technical data Yonos MAXO /-D
Specification
Permissible fluid temperature
Permissible ambient temperature
Maximum relative humidity
Mains voltage
Residual current ∆I
Electromagnetic compatibility
46
Pump designation
Single pump (without code letter)
Twin-head pump
Single pump for domestic hot water circulation systems
Flange connection DN 32
0.5: Minimum delivery head in m
11: Maximum delivery head in m
at Q = 0 m³/h
Installation and operating instructions • Wilo-Yonos MAXO/-D/-Z • Ed.01/2022-08
Value
-20 °C ... +110 °C
-20 °C ... +40 °C
≤ 95 %
1~ 230 V +/-10 % 50/60 Hz
≤ 3.5 mA
Interference emission in acc. with:
EN 61800-3:2004+A1:2012/residential environment
(C1)
Interference immunity in acc. with:
EN 61800-3:2004+A1:2012/industrial environment
(C2)