A-Home: the sensor will not trigger the alarm if the central unit is in Home mode
. This mode
can be paired for example with PIR sensors inside the house, so that when you activate the Home
mode
s, you can enter your home without triggering the alarm, providing both perimeter and
outside protection thanks to the presence of the door/window sensors that remain active because
they are not paired with this mode.
B-Delayed: You can set sensors delays in relation to alarm system triggering. Recommended
function for example for door/window contacts.
C-Normal: the sensor will trigger will trigger the alarm when the central unit is armed
or in
.
Home mode
D-24h: Regardless of whether the system is armed or disarmed, the paired sensors will remain
24hrs active. Useful with smoke detection sensors.
For this association, act directly on the jumpers located inside (6 for the magnetic contact, 7
for the PIR).
A
B
C
D
D0
D0
D0
D0
D0
D0
D0
D0
D0
D0
D0
D0
D0
D0
D0
D0
D3
D3
D3
D3
D3
D3
D3
D3
D3
D3
D3
D3
D3
D3
D3
D3
Total resent
Press the Switch button and the SOS button at the same time. Release them after an acoustic
confirmation (3 beeps). Wait for 10 seconds. The central unit emits 2 beeps: The system has
been reset to factory values. All telephone numbers stored and the accessories will be deleted