Connecting the inverter

8.3

Mounting the inverter

➤ Hold the inverter against the installation location and mark the fastening
points (fig. 3 A, page 3).
➤ Attach the inverter using your chosen fastening method (fig. 3 B,
page 3).
9
Connecting the inverter
9.1

General instructions

!
WARNING!
 The inverter may only be connected by a qualified workshop.
The following information is intended for technicians who are
familiar with the guidelines and safety precautions to be
applied.
 Never use the inverter on vehicles where the positive terminal
of the battery is connected to the chassis.
 If you do not fit a fuse to the positive cable, the cables can
overload, which might result in a fire.
 Reversed polarity can damage the inverter.
 The inverter should not be used to connect to a ring main, it
must only be used to power individual appliances that are
plugged into the inverter outlet either directly or using a pur-
pose-made, moulded extension lead
 When installed in vehicles or boats, the inverter must be connected to the
chassis or earth.
 When setting up a socket distribution circuit (mains setup), comply with
the applicable regulations.
 Only use copper cables.
 Keep the cables as short as possible (< 1.8 m).
 Keep to the specified cable cross section and fit a cable fuse (fig. 6 3,
page 5) as close to the battery as possible on the positive cable (see the
table).
Device
MSI924M
38
Required cable
cross section
25 mm²
MSI924M
Cable fuse
(fig. 6 3, page 5)
75 A