Risk of injury due to high rope
WARNING
tension
The ropes are under high tension. Dam-
aged ropes can tear and cause severe
injuries.
•
Prior to replacing damaged ropes or
springs, secure the door against un-
controlled movements.
•
Regularly check the ropes. Dam-
aged ropes must be replaced imme-
diately.
3
Product description
3.1
General product overview
Fig. 1: Product view
3.2
Technical data
Model specifications
Product:
Door size / weight
Temperature range:
Sound pressure level L
Manufacturer:
3.3
Rating plate
The rating plate is situated on the inside of the door
leaf.
20 - EN
iso20-4 ZF
iso45-5 ZF
see rating plate
+40 °C
-20 °C
≤ 70 dB(A)
pA
Novoferm GmbH
Isselburger Straße 31
46459 Rees (Haldern),
Germany
www.novoferm.de
4
Mounting
4.1
Safety information for installation and
assembly
•
The installation may only be carried out by
suitably qualified installers, see chapter 2.3 -
Personnel qualifications.
•
Read these installation instructions before you
start installing the product.
•
Never carry out the installation on your own.
Some of the work steps can only be achieved
with two people working.
•
Wear your personal protective equipment upon
installation.
4.2
Scope of delivery
The scope of delivery is determined by the product
configuration. The scope of supply usually comprises
the following:
•
Packet with sections
•
Packet with frame
•
Packet for installation
4.3
Preparing for installation
4.3.1 Information regarding installation
Observe the following information before starting the
installation:
•
The steps for installation described in these
assembly and operating instructions refer to a
standard installation. Please contact the
manufacturer regarding special mounting
conditions.
•
Prior to assembly, preventively compare the
dimensions of the garage by comparing them to
the basic dimensions of the door.
– minimal internal width of the garage = width of
basic dimension + 160 mm
– minimum garage height up to ceiling = height
of basic dimension + 115 mm (manually
operated and NovoPort)
– minimum garage height up to ceiling = height
of basic dimension + 130 mm (ceiling pull)
– minimum width stop, right and left = 35 mm
•
Check the dimensions of the garage door
opening and compare them to the dimensions
specified on the delivery note.
•
Check whether the supplied wooden screws (S8)
and the plugs (S9) are suitable for the respective
structural conditions.
•
All right/ left specifications regarding the
installation refer to the perspective from the
inside of the garage, i.e. the viewing direction is
towards the outwards direction!
•
All specified dimensions are in millimetres.
Subject to technical changes.
These assembly, operation and maintenance instructions must be kept for the entire period of use!