7.
You can move the movable guard manually to
the maximum open position.
To remove the saw blade, manually hold
the guard in the open position.
8.
Turn the disconnected machine onto the motor
unit. The saw blade points upward.
9.
Remove the old saw blade.
Clamping flanges must be free of
adhering parts!
The new saw blade can now be installed.
10. Position the new saw blade (14) on the rear
flange (16).
Ensure that the direction of rotation is
correct when you install the saw blade.
The saw teeth or the arrow on the saw
blade (14) must point in the direction of
the arrow (15) on the machine.
You can now release the movable guard.
11. Fit clamping flange (13) and flange screw (12).
12. Press and hold the locking pin (see Fig. 7:
Locking the saw blade).
13. Using the Allen key (B), turn the flange screw
(12) clockwise to tighten it.
You can now release the locking pin.
The saw blade is changed.