Dexter 800ETC1 Manual De Instrucciones página 121

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
Jolly lenght
FR
Max. workpiece thickness 90°
Max. workpiece thickness 45°
ES
Diamond cutting wheel
Nominal mass
PT
Max. operating mass of machine
Note: Recommendation for the operator to wear hearing protection.
IT
The machine is designed for operating in S1 mode (continuous operation) under 800W power and S2
mode (short-term operation) under 900W power. S2 mode means that you can operate the machine for
an uninterrupted period of 10 minutes at most with a nominal load after this period of time has
EL
used again for a maximum of 10 minutes.
PL
Sound and vibration
The noise emission values were measured in accordance with EN 61029 and EN 12418.
UA
L
sound pressure level
pA
K
uncertainty
pA
RO
L
sound power level
WA
K
uncertainty
WA
EN
Note:
that the declared noise emission value(s) have been measured in accordance with a standard test
method and may be used for comparing one tool with another;
that the declared noise emission value(s) may also be used in a preliminary assessment of exposure.
Warning:
on the ways in which the tool is used especially what kind of workpiece is processed;
need to identify safety measures to protect the operator that are based on an estimation of exposure in
the actual conditions of use (taking account of all parts of the operating cycle such as the times when
Suggestions:
1) Wear gloves while using the tool.
2) Limit the time spent using the tool.
Residual risks
Even if you use this electric power tool in accordance with the instructions, certain residual risks cannot
be eliminated. The following hazards may arise as a result of the equipment's construction and layout:
1. Lung damage if no suitable protective dust mask is used.
2. Damage to hearing if no suitable ear protection is used.
3. Damage to health caused by hand-arm vibrations if the equipment is used over long periods of time
or is not properly guided and maintained.
WARNING ! This machine is likely to emit non-ionizing radiation,
medical implants. To reduce the risk of serious or fatal injury, we
recommend persons with medical implants to consult their
physician and the medical implant manufacturer before
operating this machine.
610 mm
35 mm
27 mm
ø200 x ø25,4 mm
35 kgs
60 kgs
75 dB(A)
4 dB(A)
89 dB(A)
4 dB(A)
121

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

20035.1