E N G L I S H
Re-loading the Tool
Open the tail jaws of the tool, by switching off the tail jaw switch (18-19).
Open the jaws and pull the empty mandrel and follower spring out of the tool.
Insert the new mandrel against the stop within the too, and close the Tail Jaws 32 which grip the mandrel, by switching on
the tail jaw switch (18 and 19).
Close the Tail Jaws 32.
4.4 OPERATING PROCEDURE
You must check that the cursor orientation and the nose equipment are correct before attempting to operate the tool.
•
Push the fastener, protruding from the nose jaws, fully into the application holes ensuring that the tool is held square.
•
Operate the trigger without releasing - the mandrel head is pulled through the fastener, forming the fastener into the
application.
•
Remove the tool.
•
Release the trigger. The next fastener will be automatically presented through the nose jaws, ready for placing.
Item numbers in bold refer to the general assembly and parts list for the 07536-02200 Tool on pages 18-19.
12
IMPORTANT
O R I G I N A L I N S T R U C T I O N