3.2
Technical data
Nominal load according to EN 1398
Permissible inclination of the dock leveller platform according to
EN 1398
Permissible ambient temperature for gas spring
Maximum permissible traversing speed
Sound pressure level L
3.2.1 Door dimensions
A
B
Fig. 2: Exemplary representation, illustration may deviate from the product
OL
Overall length (NL + 300 mm)
IL (GL)
Inclination length (NL + 165 mm)
NL
Nominal length
NW
Nominal width
Installation
NL
condition
CX
400
FX
400
RX
400
NW: 1750, 2000 and 2200
All dimensions in mm.
These assembly, operation and maintenance instructions must be kept for the entire period of use!
pA
O L
G L
N L
L L
DH
500
410
500/585
60 kN
40 kN (for forklift trucks with very small
wheels)
12.5 % (7°)
−20 °C ... +80 °C
7 km/h
< 70 dB(A)
N W
B H
HL (LL)
Hinged lip length
DH (BH)
Design height
A
Upper bridging
B
Lower bridging
A (LL = 300)
100
100
100
B (LL = 300)
100
100
100
EN - 21